Skip to content
Engineering tool

Vacuum gripper & suction cup calculator

Size suction cups for a robot gripper using the three standard load cases published in Schmalz’s Vacuum Knowledge system-design guide.

Minimum cup diameter

—mm effective
Required holding force
—
Force per cup
—
Suction area per cup
—

Load cases

The three load cases, the friction reference values and the safety-factor guidance on this page follow the system-design method in Vacuum Knowledge, the published calculation guide of vacuum component maker J. Schmalz GmbH (the guide’s worked example ends in a per-cup suction force, FS = FTH ÷ n, exactly as calculated here).

  • I — horizontal gripper, vertical move: F = m × (g + a) × S
  • II — horizontal gripper, horizontal move: F = m × (g + a ÷ μ) × S
  • III — vertical gripper, vertical move: F = (m ÷ μ) × (g + a) × S

Required area per cup = F ÷ (number of cups × vacuum level). Diameter = √(4 × area ÷ π). With g = 9.81 m/s² and 1 kPa = 0.001 N/mm².

Worked example

On the pre-filled values — a 10 kg part, 5 m/s² acceleration, 4 cups, −60 kPa vacuum, safety factor 2 and load case I — the required holding force is 10 × (9.81 + 5) × 2 = 296.2 N, or 74.1 N per cup, which needs 1,234 mm² of effective area per cup and a minimum effective cup diameter of about 39.6 mm.

Before you order cups

  • The result is the effective suction diameter. Real cups lose area when they compress; check the theoretical suction force in the cup datasheet, not just the nominal size.
  • Use a safety factor of at least 1.5; vacuum makers generally recommend 2 or more for porous, oily or flexible parts and for rotation during transfer.
  • Porous parts (cardboard, wood, textiles) leak — the vacuum level you can hold depends on the generator flow, not just its rated vacuum.
  • Friction values are typical starting points. Test with real parts.