The formula
S = K × T + C, where T is the total stopping time (machine + control + protective device) in seconds.
- Resolution d ≤ 40 mm (finger and hand detection): C = 8 × (d − 14). Use K = 2000 mm/s; if S is 100–500 mm keep it (minimum 100 mm). If S exceeds 500 mm, recalculate with K = 1600 mm/s; S may then not be less than 500 mm.
- 40 mm < d ≤ 70 mm (body detection): S = 1600 × T + 850.
Worked example
With a 100 ms machine stopping time, a 20 ms light-curtain response and a 14 mm resolution, T = 0.12 s and C = 8 × (14 − 14) = 0, so ISO 13855:2010 gives a minimum distance S of 2000 × 0.12 + 0 = 240 mm.
With a slower machine — 280 ms stopping time plus 20 ms response, and a 30 mm resolution — T = 0.30 s and C = 8 × (30 − 14) = 128 mm. The first pass, 2000 × 0.30 + 128 = 728 mm, exceeds 500 mm, so the formula is recalculated with K = 1600 mm/s: S = 1600 × 0.30 + 128 = 608 mm (and the recalculated S may not fall below 500 mm).
Limits of this tool
- It covers perpendicular approach to a vertical light curtain only — not parallel (horizontal) or angled approach, multi-beam devices, reaching over the field, or area scanners.
- ISO 13855 was revised in 2024. These are the ISO 13855:2010 / EN ISO 13855:2010 formulas. Check which edition applies in your market and confirm the result against it.
- The result is an input to your risk assessment, not a substitute for it. Have a qualified safety engineer validate the installation — see our ISO 10218:2025 robot safety overview for how safeguarding fits into cell compliance.